Innovative leading-edge design results in a lighter, more compact unit with high technology features:
Patented unique "Voltage Inflection Point" DetectionDesigned for rapid operator payback, the BC-1300 Series of Main Ship Battery Chargers significantly reduces battery and charger maintenance while eliminating the guess work of identifying and solving battery/charger problems. Securaplanes new, innovative battery chargers use advanced DC to DC conversion technology, patented charging algorithms, comprehensive diagnostics and fault isolation.
Old technology chargers typically gauge the charge time based solely according to the cell voltage. This has led to either over-charging or under-charging the battery, with resulting water loss and increased maintenance.
Patented Battery Charging Method:
Securaplane has developed a method for accurately detecting the
inflection point - a feat that has eluded battery experts
for years and is critical in reducing overcharge and boiling of electrolyte.
This method of
charging ensures that the battery received the optimum amount of charge
for all temperature conditions combined with various battery states
of charge. Securaplane was awarded patent number 5,780,994 for this
method.
Reliability:
Many of todays battery chargers are dependent upon fanless ambient
convection cooling - which in most aircraft is inadequate to maintain
charger semiconductor components at suitable temperatures for extended
life operation. This is a risky design process considering that semiconductor
reliability halves for each 10°C rise in ambient. Securaplane has
found that a proven high reliability fan, used only on demand,
provides and overall improvement to charger reliability, while significantly
decreasing charger weight and volume.
Fault Storage:
BC-1300 Series chargers store every fault including battery over-temperature,
cell unbalance, defective temperature sensors, defective charger - battery
connection and GMT time/date of fault period.
Extensive Diagnostics with Alphanumeric Display: Microprocessor provides
status and permanent memory of faults with readout to the self-contained
8-character alphanumeric display.
|
Securaplane has worked with airline operators and battery manufacturers to eliminate these problem issues. As a result, the Securaplane Battery Charging System offers:
Real-Time Status Information. |